From: Tony White (tony@databit.net)
Date: Tue Mar 19 01:55:19 2002
Hi, For servers, setting 'network server mode' in the SCU (F10 setup) lets the boot continue past the message. For desktops, SP0667 (No_F1.com) sets a bit in the cmos to do the same thing. Tony At 04:13 19/03/2002 , ard@waikato.ac.nz said: > > I was testing the servers with only 1 power supply (not both redundant) > >...and the server waited for him to press a function key. > > >That annoys me no end. If one of my servers loses one of its supplies of >power and then reboots for some other reason, I want it to come up >without an operator having to go to its console and press a key. > >Is there any way of setting a timeout or cancelling the prompt so that >the boot proceeds unattended? > >-- >_________________________________________________________________________ >Andrew Donkin Waikato University, Hamilton, New Zealand > >--------------------------------------------------------------------- >To unsubscribe, e-mail: compaqandlinux-unsubscribe@van-dijk.net >For additional commands, e-mail: compaqandlinux-help@van-dijk.net >For the archives : http://www.van-dijk.net --------------------------------------------------------------------- To unsubscribe, e-mail: compaqandlinux-unsubscribe@van-dijk.net For additional commands, e-mail: compaqandlinux-help@van-dijk.net For the archives : http://www.van-dijk.net
This archive was generated by hypermail 2.1.3 : Thu Dec 19 04:00:05 2002 EST